PSkylight Consulting Group llc
SKYLIGHT DESIGNS AND FORENSIC ANALYSIS
NEW CONSTRUCTION AND REPAIR/RETRO-FITS
METAL-FRAMED SKYLIGHT SYSTEMS
SKYLIGHT TESTING AND CERTIFICATIONS
SMOKE VENT INSPECTION AND CERTIFICATION
SMOKE VENT CODE CONSULTING & DESIGN
ENERGY CODE/TITLE 24 COMPLIANCE
SKYLIGHT SAFETY AND OSHA FALL-PROTECTION
UNIT SKYLIGHT DESIGNS
ENERGY ANALYSIS WITH SKYCALC SIMULATIONS
ABOUT
OUR TEAM FEATURES OVER 130 YEARS OF EXPERIENCE IN THE FOLLOWING AREAS
* DESIGNS FOR A MULTITUDE OF SKYLIGHT SYSTEMS
* SKYLIGHT GLAZING REQUIREMENTS AND RECOMMENDATIONS
* SKYLIGHT NATIONAL ENERGY CODES AND CA TITLE 24 ENERGY CODE
* SKYLIGHT FRAME FINISH RECOMMENDATIONS
* METAL-FRAMED SKYLIGHT DESIGNS AND SPECIFICATIONS
* UNIT SKYLIGHT DESIGNS AND SPECIFICATIONS
* HEAT AND SMOKE VENT AREA CALCULATIONS AND DESIGNS
* UL LISTED AND FM APPROVED SMOKE VENTS
* SKYCALC SIMULATIONS AND DESIGN ANALYSIS FOR UNIT SKYLIGHTS
* METAL-FRAMED SKYLIGHT STRUCTURAL CALCULATIONS
* SKYLIGHT LOADS, CURB DESIGNS AND STRUCTURAL ANALYSIS
* SAFETY AND FALL-PROTECTION SOLUTIONS AND CODE REQUIREMENTS
* OSHA FALL-PROTECTION REQUIREMENTS AND RECOMMENDATIONS
* EXPERT WITNESS REVIEW AND TESTIMONY FOR SKYLIGHT FALL-THROUGHS
Paul Simony - Principal
Over 34 years of Technical Skylight, Smoke Vent, and Fall-protection experience
AAMA Skylight Council Member - 25 years
Chairman and Vice-Chair for numerous AAMA Standards, Skylight Design Guide
Skylight Installation Manual Committee Member
Skylight Fall-protection White Paper
Skylight Marketing Committee
Design Guide for Sloped Glazing, Skylight Codes and Standards Committee,
Plastic Skylights and Sloped Glazing Review Task Group
SkyCalc Development Task Group Member
Glass Design for Sloped Glazing Standard- Task Group
AAMA Smoke Vent Task Group Chairman - 11-years
NAFS AAMA A440 Development Task Group Committee Member
NFRC - Committee Participant - Skylight Testing and Certification
NFRC - Committee Member - Standard Testing for Non-planar skylight glazing
NFPA Technical Committee on Smoke Management - 10-year member
NFPA 204 Standard - Task Group Chair
NFPA High-piled Storage Committee Member
NRCA Presenter - Skylight Safety and Fall-protection
Presenter - OSHA Safety Procedures when working around Skylights
Presenter - Proper Skylight Installation Methods
Presenter - Smoke And Heat Vent Inspection and Testing Procedures
AIA Presenter - Photovoltaic Glass for Metal-framed Skylights and Canopies
Presenter - Multi-Wall Polycarbonate glazing systems for skylights and canopies
Presenter - Aerogel Insulation for Skylights
Presenter - Thermal-breaks and Thermal Barriers for skylight systems
Presenter - International Fire Code (IFC) Requirements for Heat and Smoke Vents
ASTM Committee Member - Working Group E065100.25 - Human Impact of Commercial Skylights
CalOSHA - Title 8 Review Committee for skylight fall-protection
ASHRAE - Non-residential and high-rise residential review committee for skylights
ICC-ES AC16 Review Task Group